True Blue Power Gen5 TB60 60 Amp Hour
Features
- 60 amp-hour nominal at 23°C/73°F
- Weighs 52.9 lbs. — up to 60% less than lead-acid and NiCad solutions
- Advanced NanoPhosphate® lithium-ion cell chemistry
- Higher voltage during engine start — Less wear, less maintenance and increased useful life
- Superior high-temperature and cold-weather performance from -40°C to +70°C (-40°F to +158°F)
- More than 1 amp-hour per pound
- Automatic internal heater
- Overcharge, over-discharge, over-current, short circuit, over-temperature, under-temperature and charge current limiting protection
- Built-in Test (BIT) Indicator communicates real-time state-of-charge and state-of-health
- On-condition maintenance
- Designed and built in Wichita, Kansas, USA
- FAA TSO Certified
- Two-year limited warranty
Specifications
- Capacity: 60 amp-hour nominal (at 23°C/73°F)
- Charge Voltage: 28 VDC nominal
- Output Voltage: 26.4 VDC nominal
- Output Current: 425A continuous (1,500A max)
- Technology: Advanced NanoPhosphate® lithium-ion cell chemistry
- Energy Density: 66 Wh/Kg
- Charge Current Limiting: Programmable up to 8C or unlimited
- Operating Temperature: -40°C to +70°C (-40°F to +158°F)
- Weight: 52.9 lbs. (23.99 kg)
- Dimensions: 12.5" L x 14.7" W x 8.8" H
- Configuration: 24P8S; 4 parallel x 8 in series x 6
- Battery Life Expectancy: 8 years (average)
- Maintenance: On-condition
- Case: Anodized aluminum, blue
- Certification:
- FAA TSO-C179b (Class A-4B)
- RTCA DO-311A
- RTCA DO-160G
- RTCA DO-178C DAL A
- UNDOT/IATA
|